Contact Us


SINGLE-PHASE WELDING TRANSFORMERS as always, TRE.CI designs and builds its own welding transformers.
  • For alternating current spot welders: single-phase transformers

  • For direct current spot welders: triple-phase transformers with diodes in hexa-phase bridge mounted on the secondary

  • For spot welders with average frequency: transformers with or without diodes






Only first choice core laminations varnished with low loss or with oriented grains are used for its fabrication.

For primary winding, double isolated copper thread or metal straps are used, and during the winding process it is resin-bonded again, as well.

The secondary winding always in copper ribbon, beginning with 15 KVA, is always cooled using circulating water.

The finished transformer is impregnated with epoxidated resins to eliminate cavities and air bubbles.

More controls are handled during its fabrication:

  • Immediately following the primary winding
  • Once the transformer has been completed with secondary winding and core laminator
  • Prior to the resin casting
  • Installed in the machine
The available strengths are single-phase 2,4,8,13,22,38,45,60,80 KVA and triple-phase 15, 40,70,100,220  KVA.
 
welder in direct current, spot at average attendance
 
TRE-CI - here you can find welder in direct current and spot at average attendance
 
Copyright Infocom Consulting Srl